Services

Prices and details upon request

  • Accelerated Creep Test (ACT)

    Accelerated Creep Test (ACT)

    The PE 100-RC materials described in PAS 1075 are characterized by very high stress crack resistance. The verification of the stress crack resistance of PE 100-RC materials requires an acceleration of the testing procedure.

    The FNCT under Accelerated Creep Test conditions (ACT) was developed by HESSEL Ingenieurtechnik with the aim of accelerating the characterization of the stress crack behavior of PE 100-RC materials.

    The ACT is an internationally established testing procedure and is preferred for reliable quality control and batch release.

  • Tests according to PAS 1075

    Tests according to PAS 1075

    Pipes made from Polyethylene for alternative installation techniques - Dimensions, technical requirements and testing

    • Annex 1: FNCT (accelerated test conditions)
    • Annex 2: 2NCT (accelerated test conditions)
    • Annex 3: Point Loading Test (accelerated test conditions)
    • Annex 4: Penetration Test
    • Annex 5: Thermal Ageing Test
    • Annex 6: External Protective Layer Scratch Test
  • Tests according to DIN EN 12201-1

    Tests according to DIN EN 12201-1

    Plastics piping systems for water supply, and for drainage and sewerage under pressure - Polyethylene (PE) - Part 1: General

  • Tests according to DIN EN 12201-2

    Tests according to DIN EN 12201-2

    Plastics piping systems for water supply, and for drainage and sewerage under pressure - Polyethylene (PE) - Part 2: Pipes

  • Tests according to DIN EN 12814-3

    Tests according to DIN EN 12814-3

    Testing of welded joints of thermoplastics semi-finished products - Part 3: Tensile creep test

    Included:

    • Annex A.1: Tensile creep test on specimens with circumferential notch (FNCT)
    • Annex A.2: Tensile creep test on specimens with 2 notches (2NCT)
    • Annex B: Whole pipe tensile creep rupture test
    • Annex D: Testing of socket joints

    Note: The following translations of Annexes A.1, A.2 of the standard DIN EN 12814-3 are our own translations and not the original text.

  • Tests according to DIN EN 1555-1

    Tests according to DIN EN 1555-1

    Plastics piping systems for the supply of gaseous fuels - Polyethylene (PE) - Part 1: General

     

     

  • Tests according to DIN EN 1555-2

    Tests according to DIN EN 1555-2

    Plastics piping systems for the supply of gaseous fuels - Polyethylene (PE) - Part 2: Pipes

  • Tests according to DVS 2203-4

    Tests according to DVS 2203-4

    Testing of welded joints of thermoplastics plates and pipes - Tensible creep test

    Supplement 1
    Testing of socket joints

    Supplement 2
    Tensile creep test for resistance to slow crack growth in the full notch creep test (FNCT)

    Supplement 3
    Checking the required tensile creep test weld strength reduction factor and the minimum service life of polyethylene welded joints (PE 80 andPE 100)

    Supplement 4
    Tensile creep test for resistance to slow crack growth in the two notch creep test (2NCT)

  • Tests according to ISO 16770

    Tests according to ISO 16770

    Plastics - Determination of environmental stress cracking (ESC) of polyethylene - Full-notch creep test (FNCT)